Car, GWM, TANK 500, International Fuel, Air conditioner (AC)

Climate control - Air conditioner (AC) - 0

Identification

Fingerprint: --

UIN: --

Factory mode: --

Manufacture bootloader software version number: --

ECU calibration software - version number: --

Tool version: --

Name:

Comp identifier 1: --

Node - address: --

Identifier: --

ECU - level network configuration: --

Application software - programming success counter: 0

Maximum allowable program number: 0

Application software programming attempt counter: 0

Supplier ECU boot software version number: --

C-Matrix version: --

System supplier ECU software version number: --

System supplier ECU hardware version number: --

Vehicle identification number: --

System supplier identifier data: --

Vehicle manufacturer ECU software version number: --

Vehicle manufacturer spare part number: --

DTC

Controls

Clear DTC

Data stream

Operating voltage: 0.00 V

EXV - run status: --

A/C compressor - power limit: 0 W

EAH_heatg_request: 0

EAH - enable operation: --

EAH - reset request: --

Cooling fan - output status: --

A/C rear blower - feedback voltage: 0.00 V

Front blower - voltage feedback: 0.00 V

Rear warm stop valve - output status: --

Rear evaporator stop valve - output status: --

Second row left foot temperature sensor: -20.00 °C

Second row left face temperature sensor: -20.00 °C

Rear left foot temperature sensor: -20.00

Rear left face temperature sensor: -20.00 °C

In-car temperature sensor rear: -20.00 °C

Rear evaporator temperature sensor: -20.00 °C

Right solar sensor - intensity: 0

Rear air distribution flap - position: 0 %

Second row air distribution - position: 0 %

Rear left temperature flap - position: 0 %

Second left temperature flap - position: 0 %

Rear blower voltage: 0.00 V

Low power supply relay - status: --

Electronic pump - PWM signal: 0 %

Fragrance channel 3 - type: 0

Fragrance channel 2 - type: 0

Fragrance channel 1 - type: 0

Fragrance channel 3 - illegality status: --

Fragrance channel 2 - illegality status: --

Fragrance channel 1 - illegality status: --

Fragrance channel 3 - fragrance available time: 0

Fragrance channel 2 - fragrance available time: 0

Fragrance channel 1 - fragrance available time: 0

Fragrance channel 3 - timeout alarm: --

Fragrance channel 2 - timeout alarm: --

Fragrance channel 1 - timeout alarm: --

Fragrance channel - type: --

Fragrance - enable: --

Fragrance level resp: --

PM2.5: --

PM2.5 air in quality level: --

PM2.5 in den: 0

FWV - real station: 0.00

EAH PCB - temperature: -50 °C

EAH: --

EAH: 0 V

EAH: 0.00 A

EXV (electric expansion valve) - current position: 0

EXV (electric expansion valve) - move enable: --

EXV (electric expansion valve) - current initialization: --

EAC_comp_IGBT_temperature: -40 °C

EAC_compare_power_consumption: 0 W

EAC_comp_HV_input: 0

EAC_comp_elec_current: 0.00 A

EAC_comp_speed: 0

EAC_compressor_state: --

Cycle valve - status: --

Front evaporator stop valve: --

Driver foot temperature sensor: -20.00 °C

Driver face temperature sensor: -20.00 °C

Passenger foot temperature sensor: -20.00 °C

Passenger face temperature sensor: -20.00 °C

PT sensor 1: -20.00 °C

PT sensor 1: 0 kPa

Pressure sensor: 0

External control valve: 0.00 A

External control valve - PWM: 0.00

Front blower relay: --

Supply voltage for ION status: --

Compressor OFF code: --

Air quality sensor - PWM duty cycle: 0 %

In-car temperature sensor front: -30.00 °C

Rear defogger relay: --

Rear defog feedback: --

Front evaporator temperature sensor: -20.00 °C

Ambient temperature sensor: -40.00 °C

Left solar sensor - intensity: 0

Front air distribution - position: 0 %

Passenger temperature flap - position: 0 %

Driver temperature flap - position: 0 %

Fresh air and recirculated air flap position: 0 %

Front blower control: 0.00 %

Stepper supply 12V: --

EAH - inlet water temperature: -50.00 °C

EAH - on duty cycle: -50.00 %

Actuators test

Controls

Stepper motor supply 12V

Front blower control

Fresh air flap motor position

Left temperature flap motor

Right temperature flap motor

Front air distribution position

Left solar sensor

Outside air temperature sensor

Front evaporator temperature sensor

Rear defogger relay feedback

Rear defogger relay

Front in-car temperature sensor

Air quality sensor

Supply voltage for ION

Front blower relay

Pressure sensor

PT sensor 1 pressure

PT sensor 1 temperature

Right outlet temperature sensor (face level)

Right outlet temperature sensor (foot level)

Left outlet temperature sensor (face level)

Left outlet temperature sensor (foot level)

Front evaporator stop valve control

Electronic pump enable status control

Cycle valve control

Electronic pump PWM control

EXV relay control

EXV position

EXV_Initn_Req

EXV stall test request control

EXV_Move_Ena

EAC_comp_speed_request_control

EAC_comp_limit_power_control

EAC_comp_state_control

EAH_heatg_request_control

EAH_enable_oper_control

EAH reset request control

PM2.5_sts_request_control

FGA enable request control

FGA channel type control

FGA level request control

Rear blower voltage control

Rear row left temperature flap position control

Second row air distribution postion control

Right solar sensor

Rear evaporator temperature sensor control

Rear in-car temperature sensor control

Rear left face temperature sensor

Rear left foot temperature sensor

Rear evaporator stop valve control

Utility

Controls

Edit VIN

Configuration

Controls

ECU level network configuration